Products - Microprocessors |
TCS Miniature RTD Transmitter

RTD-TC-Cal Computer Interface Module / RTD-TC, RTD Transmitter Coupling (BACK) / RTD-TC, RTD Transmitter Coupling (FRONT)
|
Application: RTD-TC, RTD-Transmitter Connector for direct connection to OEM PRTD probes. The transmitter connector is a stainless steel housed, miniature, isolated, software programmable, 4-20 mA transmitter designed to be coupled to a 100 ohm, 3 wire, 385 single RTD probe fitted with three pin standard connector. Generally used in high accuracy applications. The PRTD assembly can be recalibrated at any time, to check sensor stability and or extend the useful life of the RTD probe.
Termination:
Temperature rating:
Detailed Engineering Specifications Performance Specs: at Tambient = 25 oC Vnom = 24 VDC
RTD-TC
Transmitter Specifications
Scaling (programmable)
Within min span, see
ranges below
Ranges (fixed)
Calibration (programmable)
1 or 2 point calibration
23 mA or 2.5 mA
Output
4-20 mA linear
Power Supply Variability
9 to 32 VDC
Supply Effect
0.01% (of reading) /V
Accuracy
Maximum Error, one point
calibration
Maximum Error, two point
calibration
Error at Calibration Points 1
+/- .25 oC + 0.4% of
reading
+/- .10 oC + 0.1% of
reading
less than 0.1 % of span
Maximum
(power supply- 9)V/20mA
Isolation
500 VDC Input
(between probe and supply)
Temperature Stability
Less than or equal to
+/- (0.005% (of reading) + 0.015)
oC/oC
(from ambient @ 25 oC)
Ambient
-40 to 80 oC
Enclosure Rating
NEMA 6P
OEM PRTD
Specifications
RTD Element Type
Platinum, alpha = 0.00385 , 100
ohm
RTD Element Design
Thin Film, Helix or Mandrel Wound
PRTD Sensor Execution
Single Element, Three Wire
Related Specifications
IEC751,OIML 1985,DIN 43760, BS
1904:1984,COST 6651-84
Notes
Based on ice point and comparison bath
calibration methods and associated calibration tolerances using
traceable reference standards and appropriate calibration
procedures.
Color Code:
Accessories: Calibration Module RTD-TC-Cal for programming zero and span and for programming
Span Fault Output O Two Point Calibration |
|
|